MR angiography and 2-D phase-contrast imaging for evaluation of meso-rex bypass function
Heather A Stefek1,2, Cynthia K Rigsby3,4, Haben Berhane3
1Northwestern University Feinberg School of Medicine, 420 E. Superior St., Chicago, IL, 60611, USA. heather.stefek@northwestern.edu.
Background:
The meso-Rex bypass restores blood flow to the liver in patients with extrahepatic portal vein thrombosis. Stenosis occurs in some cases, causing the reappearance of portal hypertension. Complications such as thrombocytopenia present on a spectrum and there are currently no guidelines regarding a threshold for endovascular intervention. While Doppler ultrasound (US) is common for routine evaluation, magnetic resonance (MR) angiography with two-dimensional phase-contrast MRI (2-D PC-MRI) may improve the assessment of meso-Rex bypass function.
Objectives:
To determine the feasibility and utility of MR angiography with 2-D PC-MRI in evaluating children with meso-Rex bypass and to correlate meso-Rex bypass blood flow to markers of portal hypertension.
Materials And Methods:
MR angiography and 2-D PC-MRI in meso-Rex bypass patients were retrospectively analyzed. Minimum bypass diameter was measured on MR angiography and used to calculate cross-sectional area. Meso-Rex bypass blood flow was measured using 2-D PC-MRI and divided by ascending aortic flow to quantify bypass flow relative to systemic circulation. Platelet and white blood cell counts were recorded. Correlation was performed between minimum bypass area, blood flow and clinical data.
Results:
Twenty-five children (median age: 9.5 years) with meso-Rex bypass underwent MR angiography and 2-D PC-MRI. The majority of patients were referred to imaging given clinical concern for complications. Eighteen of the 25 patients demonstrated >50% narrowing of the bypass cross-sectional area. The mean platelet count in 19 patients was 127 K/μL. There was a significant correlation between minimum cross-sectional bypass area and bypass flow (rho=0.469, P=0.018) and between bypass flow and platelet counts (r=0.525, P=0.021).
Conclusion:
Two-dimensional PC-MRI can quantify meso-Rex bypass blood flow relative to total systemic flow. In a cohort of 25 children, bypass flow correlated to minimum bypass area and platelet count. Two-dimensional PC-MRI may be valuable alongside MR angiography to assess bypass integrity.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Phase Diagrams
Phase Transitions
Phase Transitions: Sublimation and Deposition
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...