Related Experiment Video
Updated: Feb 3, 2026

A Mouse Model of Orotracheal Intubation and Ventilated Lung Ischemia Reperfusion Surgery
Published on: September 9, 2022
Peep titration based on the open lung approach during one lung ventilation in thoracic surgery: a physiological study
Michela Rauseo1,2, Lucia Mirabella3, Salvatore Grasso4
1Department of Anesthesia and Intensive care, University of Foggia, Viale Pinto, 1-71100, Foggia, Italy. michela.rauseo@hotmail.it.
Background:
During thoracic surgery in lateral decubitus, one lung ventilation (OLV) may impair respiratory mechanics and gas exchange. We tested a strategy based on an open lung approach (OLA) consisting in lung recruitment immediately followed by a decremental positive-end expiratory pressure (PEEP) titration to the best respiratory system compliance (CRS) and separately quantified the elastic properties of the lung and the chest wall. Our hypothesis was that this approach would improve gas exchange. Further, we were interested in documenting the impact of the OLA on partitioned respiratory system mechanics.
Methods:
In thirteen patients undergoing upper left lobectomy we studied lung and chest wall mechanics, transpulmonary pressure (PL), respiratory system and transpulmonary driving pressure (ΔPRS and ΔPL), gas exchange and hemodynamics at two time-points (a) during OLV at zero end-expiratory pressure (OLVpre-OLA) and (b) after the application of the open-lung strategy (OLVpost-OLA).
Results:
The external PEEP selected through the OLA was 6 ± 0.8 cmH2O. As compared to OLVpre-OLA, the PaO2/FiO2 ratio went from 205 ± 73 to 313 ± 86 (p = .05) and CL increased from 56 ± 18 ml/cmH2O to 71 ± 12 ml/cmH2O (p = .0013), without changes in CCW. Both ΔPRS and ΔPL decreased from 9.2 ± 0.4 cmH2O to 6.8 ± 0.6 cmH2O and from 8.1 ± 0.5 cmH2O to 5.7 ± 0.5 cmH2O, (p = .001 and p = .015 vs OLVpre-OLA), respectively. Hemodynamic parameters remained stable throughout the study period.
Conclusions:
In our patients, the OLA strategy performed during OLV improved oxygenation and increased CL and had no clinically significant hemodynamic effects. Although our study was not specifically designed to study ΔPRS and ΔPL, we observed a parallel reduction of both after the OLA.
Trial Registration:
TRN: ClinicalTrials.gov , NCT03435523 , retrospectively registered, Feb 14 2018.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Related Concept Videos
Lung Capacity
Acid-Base Titration Curves
For a titration carried out for 25.00 mL of...
Pleura of the Lungs
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Gross Anatomy of the Lungs