Prolonged In-use Stability of Reconstituted Herceptin in Commercial Intravenous Bags

Heiko Nalenz1, Ellen Köpf2, Elke Dietel2

  • 1F. Hoffman-LaRoche Ltd., Basel, Switzerland. heiko.nalenz@roche.com.

Herceptin is a humanized monoclonal antibody that selectively binds to the extracellular domain of human epidermal growth factor receptor 2 (HER2). Herceptin has an important role in the treatment of HER2-positive breast cancer when used in the neoadjuvant, adjuvant, and metastatic settings, and in the treatment of HER2-positive metastatic gastric cancer, and gastroesophageal junction adenocarcinoma. Prior to intravenous infusion, Herceptin must be reconstituted with sterile water for injection and then diluted in intravenous bags with normal saline. The objective of this study was to test the in-use physicochemical stability of the Herceptin drug product after dilution in 0.9% sodium chloride in commercial polyvinylchloride, and polyolefin/ polyethylene/polypropylene infusion bags over the course of a 7-day storage at 2°C to 8°C followed by 24 hours of storage at 30°C with ambient light exposure. Three batches of Herceptin were reconstituted to yield a 21-mg/mL solution that was stored for 48 hours at 2°C to 8°C prior to dilution with 0.9% sodium chloride to create low (0.24-mg/mL) and high (3.84-mg/mL) concentration solutions that were then tested in simulated infusions with a polyvinylchloride or polyolefin/polyethylene/polypropylene infusion bag. Samples for analysis were obtained immediately after dilution of the reconstituted solution (T0), after 7 days of storage at 5°C (T7), after 1 further day of storage at 30°C (T7+1), and after administration through intravenous tubing (Tend). Control samples were obtained from bags containing only 0.9% sodium chloride at each time point. For experiments with both infusion bags, all samples were practically free from particles, were colorless, and had low numbers of subvisible particles with no differences between control and experimental samples. No change in turbidity was detected between T0 and Tend for low and high-concentration samples for each batch. The pH values remained consistent between T0 and T7+1, and osmolality values were consistent across low-concentration and high-concentration samples. Protein content, size, and potency remained consistent throughout storage and simulated infusion. In conclusion, Herceptin remains physicochemically stable for 7 days when stored at 2°C to 8°C, followed by an additional 24 hours at 30°C when diluted in 0.9% sodium chloride and stored in commercially available polyvinylchloride or polyolefin/polyethylene/polypropylene infusion bags.

Related Concept Videos

Nuclear Stability03:18

Nuclear Stability

Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together...
23.3K
RNA Stability01:53

RNA Stability

Intact DNA strands can be found in fossils, while scientists sometimes struggle to keep RNA intact under laboratory conditions. The structural variations between RNA and DNA underlie the differences in their stability and longevity. Because DNA is double-stranded, it is inherently more stable. The single-stranded structure of RNA is less stable but also more flexible and can form weak internal bonds. Additionally, most RNAs in the cell are relatively short, while DNA can be up to 250 million...
35.7K
Stability01:28

Stability

The time response of a linear time-invariant (LTI) system can be divided into transient and steady-state responses. The transient response represents the system's initial reaction to a change in input and diminishes to zero over time. In contrast, the steady-state response is the behavior that persists after the transient effects have faded.
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
418
Stability of structures01:14

Stability of structures

In mechanical engineering, the stability of systems under various forces is critical for designing durable and efficient structures. One fundamental way to explore these concepts is by analyzing systems like two rods connected at a pivot point, O, with a torsional spring of spring constant k at the pivot point. This system is similar in appearance to a scissor jack used to change tires on a car. In this case, the arms of the linkage (equivalent to the rods in this system) are entirely vertical,...
523
Pole and System Stability01:24

Pole and System Stability

The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
966
Multimachine Stability01:25

Multimachine Stability

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
581