Related Experiment Video
Updated: Feb 3, 2026

Development of a Noninvasive, Laser-Assisted Experimental Model of Corneal Endothelial Cell Loss
Published on: April 24, 2020
Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery
Cristina Peris-Martínez1,2, Inmaculada Bueno-Gimeno3, Izaskun Alvarez-Arana3
1FISABIO Oftalmología Médica (FOM), Cornea and External Diseases Unit, Valencia, Spain.
Purpose:
To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia.
Methods:
Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes was performed.
Results:
A statistically significant reduction of sphere (p = 0.043) was observed at 1 month after surgery, with a significant improvement of uncorrected distance visual acuity associated (p = 0.019). Likewise, a significant reduction of anterior corneal power measurements (p ⩽ 0.014) and steepest posterior keratometric reading (p = 0.006) were observed at 1 month postoperatively, with no significant changes afterwards (p ⩾ 0.133). No significant changes were observed in manifest cylinder (p ⩾ 0.175), corrected distance visual acuity (p ⩾ 0.174), flattest posterior keratometric measurement (p ⩾ 0.282), volumetric measurements (p ⩾ 0.051), and corneal biomechanical parameters (p ⩾ 0.068). Vector analysis revealed an initial trend to overcorrection of astigmatism, with a trend to undercorrection at the end of follow-up and a significant variability in the outcome achieved in each patient.
Conclusion:
The implantation of KeraRing segments in post-LASIK corneal ectasia generates a significant modification of spherical refraction and a visual improvement due to a central corneal flattening generated. More refined nomograms of implantation in these cases should be developed to achieve a more predictable correction of astigmatism.
Related Concept Videos
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Matrix-Assisted Laser Desorption Ionization (MALDI)
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Intrinsically Disordered Proteins
Viral Recombination
CRISPR and crRNAs
The CRISPR-Cas system stores a copy of foreign DNA in the host genome and uses it to identify the foreign DNA upon reinfection. CRISPR-Cas has three different...

