Development of a high-fidelity minimally invasive mitral valve surgery simulator
Peyman Sardari Nia1, Jean H T Daemen2, Jos G Maessen1
1Department of Cardiothoracic Surgery, Maastricht University Medical Center, Maastricht, The Netherlands; Faculty of Health, Medicine and Life Sciences (FHML), Cardiovascular Research Institute Maastricht (CARIM), Maastricht, The Netherlands.
Objectives:
The aim of this study was to develop a high-fidelity minimally invasive mitral valve surgery (MIMVS) simulator.
Methods:
The process of industrial serial design was applied based on pre-set requirements, acquired by interviewing experienced mitral surgeons. A thoracic torso with endoscopic and robotic access and disposable silicone mitral valve apparatus with a feedback system was developed. The feedback system was based on 4 cameras around the silicone valve and an edge detection algorithm to calculate suture depth and width. Validity of simulator measurements was assessed by comparing simulator-generated values with measurements done manually on 3-dimensional reconstructed micro-computed tomography scan of the same sutures. Independent surgeons tested the simulator between 2014 and 2018, whereupon an evaluation was done through a questionnaire.
Results:
The feedback system was able to provide width and depth measurements, which were subsequently scored by comparison to pre-set target values. Depth did not significantly differ between simulator and micro-computed tomography scan measurements (P = .139). Width differed significantly (P = .001), whereupon a significant regression equation was found (P < .0001) to calibrate the simulator. After calibration, no significant difference was found (P = .865). In total, 99 surgeons tested the simulator and more than agreed with the statements that the simulator is a good method for training MIMVS, and that the mitral valve and suture placement looked and felt realistic.
Conclusions:
We successfully developed a high-fidelity MIMVS simulator for endoscopic and robotic approaches. The simulator provides a platform to train skills in an objective and reproducible manner. Future studies are needed to provide evidence for its application in training surgeons.
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis I: Introduction
Mitral Regurgitation I: Introduction