Related Experiment Video
Updated: Feb 3, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Metal artifact reduction MRI for total ankle replacement sagittal balance evaluation
Cesar de Cesar Netto1, Lew C Schon2, Lucas Furtado da Fonseca2
1Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 North Caroline Street, Baltimore, MD 21287, USA; Department of Orthopaedic Surgery, Medstar Union Memorial Hospital, 201 E University Pkwy, Baltimore, MD 21218, USA; Department of Foot and Ankle Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA.
Background:
Restoration of anatomical relationship between talus and tibia is crucial for longevity of total ankle replacement (TAR). Weight-bearing (WB) radiographs are the standard for evaluating the sagittal balance alignment, but are prone to rotational misalignment and altered measurements. Metal artifact reduction sequence (MARS) MRI allows visualization of periprosthetic landmarks and alignment of the image plane to the true sagittal axis of the implant. The purpose of this study was to compare TAR sagittal balance measurements on MARS MRI and WB radiographs.
Methods:
Twenty-three subjects with TAR [10 men/13 women, age 60 (41-73) years; 13 (3-24) months post-op] underwent MARS MRI and standard lateral WB radiographs. Standardized MARS MR images were aligned to the sagittal talar component axis. Three observers performed sagittal balance alignment measurements twice in an independent, random and blinded fashion. Lateral Talar Station (LTS), tibial axis-to-talus (T-T) ratio and normalized tibial axis-to-lateral-process (T-L) distance were measured. Concordance correlation coefficients (CCC) and intraclass correlation coefficients (ICC) were used for statistical analysis. In addition, mixed effects linear models were employed to assess overall concordance of the two image types.
Results:
The intraobserver agreement was excellent for radiographic (CCC=0.96) and MRI (CCC=0.90-0.97) measurements. Interobserver agreements were good-to-excellent with overall slightly higher agreements for MRI (ICC=0.78-0.94) than radiography (ICC=0.78-0.90) measurements. The T-T ratios of radiographs and MRI showed a high degree of concordance, whereas LTS was significantly lower on MRI when compared with radiographs, and T-L distance showed notable disagreement between the two imaging types.
Conclusion:
Sagittal balance measurements performed on standardized weight-bearing radiographs and standardized MARS MRI demonstrate substantial correlation and similarity. Given its high intra and interobserver agreement, MARS MRI may be helpful for the evaluation of TAR sagittal balance.
Level Of Evidence:
Level II - Prospective Comparative Study.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
09:20A Method to Manipulate Surface Tension of a Liquid Metal via Surface Oxidation and Reduction
Published on: January 26, 2016
Related Concept Videos
Balancing Redox Equations
Ankle Joint
Oxidation-Reduction Reactions
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....