Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
Impact of hemodialysis on cardiovascular system assessed by pulse wave analysis
Malgorzata Debowska1, Jan Poleszczuk1, Wojciech Dabrowski2
1Department for Mathematical Modeling of Physiological Processes, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
Abstract:
Valuable information about cardiovascular system can be derived from the shape of aortic pulse wave being the result of reciprocal interaction between heart and vasculature. Pressure profiles in ascending aorta were obtained from peripheral waveforms recorded non-invasively (SphygmoCor, AtCor Medical, Australia) before, during and after hemodialysis sessions performed after 3-day and 2-day interdialytic intervals in 35 anuric, prevalent hemodialysis patients. Fluid status was assessed by Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Germany) and online hematocrit monitoring device (CritLine, HemaMetrics, Utah). Systolic pressure and ejection duration decreased during dialysis. Augmentation index remained stable at 30 ± 13% throughout hemodialysis session despite the decrease of augmented pressure and pulse height. Subendocardial viability ratio (SEVR) determined after 3-day and 2-day interdialytic intervals increased during the sessions by 43.8 ± 26.6% and 26.1 ± 25.4%, respectively. Hemodialysis performed after 3-day and 2-day interdialytic periods reduced significantly overhydration by 2.4 ± 1.0 L and 1.8 ± 1.2 L and blood volume by 16.3 ± 9.7% and 13.7 ± 8.9%, respectively. Intradialytic increase of SEVR correlated with ultrafiltration rate (R = 0.39, p-value < 0.01), reduction in overhydration (R = -0.57, p-value < 0.001) and blood volume drop (R = -0.38, p-value < 0.01). The strong correlation between the decrease of overhydration during hemodialysis and increase in SEVR confirmed that careful fluid management is crucial for proper cardiac function. Hemodialysis affected cardiovascular system with the parameters derived from pulse-wave-analysis (systolic and augmented pressures, pulse height, ejection duration, SEVR) being significantly different at the end of dialysis from those before the session. Combination of pulse-wave-analysis with the monitoring of overhydration provides a new insight into the impact of hemodialysis on cardiovascular system.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation