Related Experiment Video
Updated: Feb 3, 2026

3D Printing of Preclinical X-ray Computed Tomographic Data Sets
Published on: March 22, 2013
Improvement of fully automated airway segmentation on volumetric computed tomographic images using a 2.5 dimensional
Jihye Yun1, Jinkon Park2, Donghoon Yu2
1Department of Convergence Medicine, Biomedical Engineering Research Center, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-Ro 43-Gil Songpa-Gu, Seoul 05505, South Korea.
Abstract:
We propose a novel airway segmentation method in volumetric chest computed tomography (CT) and evaluate its performance on multiple datasets. The segmentation is performed voxel-by-voxel by a 2.5D convolutional neural net (2.5D CNN) trained in a supervised manner. To enhance the accuracy of the segmented airway tree, we simultaneously took three adjacent slices in each of the orthogonal directions including axial, sagittal, and coronal and fine-tuned the parameters that influence the tree length and the number of leakage. The gold standard of airway segmentation was generated by a semi-automated method using AVIEW™. The 2.5D CNN was trained and evaluated on a subset of inspiratory thoracic CT scans taken from the Korean obstructive lung disease study, which includes normal subjects and chronic obstructive pulmonary disease patients. The reliability and further practicality of our proposed method was demonstrated in multiple datasets. In eight test datasets collected by the same imaging protocol, the percentage detected tree length, false positive rate, and Dice similarity coefficient of our method were 92.16%, 7.74%, and 0.8997 ± 0.0892, respectively. In 20 test datasets of the EXACT'09 challenge, the percentage detected tree length was 60.1% and the false positive rate was 4.56%. Our fully automated (end-to-end) segmentation method could be applied in radiologic practice.
Related Concept Videos
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Imaging Studies III: Computed Tomography
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Convolution: Math, Graphics, and Discrete Signals
To simplify the convolution integral, it is assumed that both the input signal and impulse response are zero for negative time values. The graphical convolution process...

