Related Experiment Video
Updated: Feb 3, 2026

Rapid Molecular Detection and Differentiation of Influenza Viruses A and B
Published on: January 30, 2017
Vertical flow-based paper immunosensor for rapid electrochemical and colorimetric detection of influenza virus using
Jyoti Bhardwaj1, Abhinav Sharma2, Jaesung Jang3
1Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.
Abstract:
We present a novel vertical flow-based paper immunosensor for the rapid and sensitive electrochemical and colorimetric detection of influenza H1N1 viruses using a different pore size (DP) sample pad. The DP sample pad consisted of two different pore size papers: larger pores (diameter: 11 µm) facing the inlet, and smaller pores (diameter: 0.45 µm) facing the conjugate pad. This sample pad offered moderate and uniform flows, and hence concentrated horseradish peroxidase tagged antibodies (HRP-Abs)-H1N1 complexes from 40 µL of sample volumes on a conjugate pad for 2 min after sample injection, thereby providing fast detection (6 min for both detection methods) with 100 µL of flushing afterwards, high sensitivity, and the simplicity of the sensor. The filtration characteristics of the DP sample pad were evaluated using fluorescent beads, indicating that only small-sized bio-particles such as viruses can pass through the sample pad. Sandwich immunoreactions of HRP-Ab-H1N1-Ab were performed on the gold paper electrode of the immunoStrip, which was determined by electrochemical impedance spectroscopy (EIS) measurements. Simultaneously, the color signal of free HRP-Ab captured on the colorimetric zone was obtained using a scanner, and the intensity was analyzed using ImageJ. This immunosensor detected H1N1 virus concentration as low as 3.3 plaque forming units (PFU)/mL (phosphate buffer saline; PBS) and 4.7 PFU/mL (saliva) by EIS, and 1.34 PFU/mL (PBS) and 2.27 PFU/mL (saliva) by the colorimetric method. Furthermore, integrating these two detection methods can reduce false results with double assurance, and this device can provide a simple and economical on-site detection platform.
Related Concept Videos
Pore Size Distribution
Adequate...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
One-Way ANOVA: Unequal Sample Sizes
One-Way ANOVA: Equal Sample Sizes
Different sample means can result in different values for the variance estimate: variance between samples. This is because the variance between samples is calculated as the product of the sample size and the variance between the...
Rapidly Varying Flow

