Reduced amblyopic eye fixation stability cannot be simulated using retinal-defocus-induced reductions in visual acuity
Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: An Automated Method for Assessing Visual Acuity in Infants and Toddlers Using an Eye-Tracking System
Published on: March 17, 2023
Rajkumar Nallour Raveendran1, William Bobier1, Benjamin Thompson1
1School of Optometry and Vision Science, University of Waterloo, Ontario, Canada.
Abstract:
Amblyopia is associated with impaired visual acuity (VA) and reduced fixation stability (FS). To assess whether impaired VA may cause reduced FS, the effects of retinal-defocus-induced visual acuity reductions on FS were measured in observers with amblyopia and controls. Fixational eye movements were measured in 8 patients with amblyopia and 12 controls. Monocular near VA of a subset of controls (n = 5) was then varied from 20/20 to 20/100 using convex lenses. The amblyopia group completed three monocular conditions; 1) amblyopic eye fixating, 2) fellow eye fixating and 3) fellow eye fixating with VA reduced to match the amblyopic eye. Fixational eye movements were quantified using bivariate contour ellipse area (BCEA) and microsaccadic amplitude. Amblyopic eye BCEA was significantly larger with increased microsaccadic amplitude compared to the fellow eye and control eyes. BCEA and VA were positively correlated for amblyopic eyes. VA impairments induced by retinal defocus did not reduce FS in controls or the fellow eye of observers with amblyopia, even when fellow eye VA was matched to that of the amblyopic eye. This suggests that reduced FS in amblyopic eyes cannot be simulated by acute VA reductions. Therefore, reduced amblyopic eye FS may not be a direct consequence of the VA loss alone. As in previous studies, a correlation between BCEA and VA for amblyopic eyes was observed. This relationship could be due to a third, mediating variable or an effect of fixational eye movements on VA.
Related Concept Videos
Oxidation-Reduction Reactions
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...