Related Experiment Video
Updated: Feb 3, 2026

Development of an In Vitro Ocular Platform to Test Contact Lenses
Published on: April 6, 2016
Long-term effect of corneoscleral contact lenses on refractory ocular surface diseases
Sang-Mok Lee1, Yu Jeong Kim2, Se Hyun Choi2
1Department of Cornea, External Disease & Refractive Surgery, HanGil Eye Hospital, 35 Bupyeong-daero, Bupyeong-gu, Incheon 21388, Republic of Korea; Department of Ophthalmology, Catholic Kwandong University College of Medicine, 24 Beomil-ro 579beon-gil, Gangneung-si, Gangwon-do 25601, Republic of Korea.
Purpose:
To report the therapeutic effect of corneoscleral contact lenses (CLs) with a diameter of 14.0 mm on the refractory ocular surface diseases.
Methods:
Medical records of 13 eyes (of nine patients) attempted for fitting with corneoscleral CLs for the management of the severe refractory ocular surface diseases were retrospectively reviewed including Stevens-Johnson syndrome (SJS; eight eyes) and chronic ocular graft-versus-host disease (GVHD; five eyes). Lenses were fitted to improve refractory punctate epithelial erosions (PEE, ten eyes) and persistent epithelial defect (PED, three eyes with SJS) despite the proper medical management. Short-term (1 month) and long-term (12 months) changes in the best corrected visual acuity (BCVA), corneal fluorescein staining (CFS) score, mean wearing time, and National Eye Institute's Visual Function Questionnaire-25 (VFQ-25) were evaluated.
Results:
Of the 13 eyes, ten eyes were successfully fitted with the corneoscleral CLs. The fitting was failed in three eyes due to small palpebral fissure and shortened fornices (two eyes) and handling difficulty (one eye). At one-month follow-up after successful fitting in ten eyes, mean wearing time was 12.6 h (6.5-17, all day long) and BCVA improved from 0.56 ± 0.59 to 0.27 ± 0.46 in logMAR (P = .018). For the eight well-fitted eyes with refractory PEE, CFS score improved from 7.38±2.20 to 5.13±2.48 (P = .024). PED improved in all two eyes which were successfully fitted with corneoscleral CLs (Of the three eyes with PED, one eye failed fitting). At 12-month follow-up, mean wearing time was 11.4 h and the improved BCVA and CFS score were maintained. Furthermore, no adverse events attributable to corneoscleral CLs use occurred.
Conclusion:
The corneoscleral CLs with a diameter of 14.0 mm were successfully fitted in ten out of 13 eyes with severe refractory ocular surface diseases and demonstrated therapeutic benefits in the well-fitted eyes. The corneoscleral CL can be an option in the management of severe refractory ocular surface diseases.
Related Concept Videos
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Long-term Depression
Long-term Depression
Calcium Ion Concentration Mechanism
If over...
Regional Terms
Primarily, the human body has two major regions, the axial and appendicular regions. The axial region comprises regions from the head to the abdomen and makes up the central body axis. In contrast,...
Long-Term Memory
Long-term memory can be categorized into two primary types: explicit and implicit memory. Explicit memory, also known as declarative memory, involves the conscious recollection of information that we deliberately try to remember, recall, and articulate. This type of memory encompasses specific facts, events, and...

