Related Experiment Video
Updated: Feb 3, 2026

Microfluidic Flow Chambers Using Reconstituted Blood to Model Hemostasis and Platelet Transfusion In Vitro
Published on: March 19, 2016
Wrong-Patient Blood Transfusion Error: Leveraging Technology to Overcome Human Error in Intraoperative Blood
Background:
Confirmation of match between patient and blood product remains a manual process in most operating rooms (ORs), and documentation of dual-signature verification remains paper based in most medical institutions. A sentinel event at Johns Hopkins Hospital in which a seriously ill patient undergoing an emergent surgical procedure was transfused with a unit of incompatible red blood cells that had been intended for another patient in an adjacent OR led the hospital to conduct a quality improvement project to improve the safety of intraoperative blood component transfusions.
Methods:
A multidisciplinary quality improvement project team led a four-phase implementation of bedside bar code transfusion verification (BBTV) for intraoperative blood product administration. Manual random sample audits of blood component transfusions were used to examine accuracy of documentation from July 2014 through June 2016. After the transition to the Epic anesthesia information management system (AIMS) in July 2016, automated Epic reports were generated to provide population-level audits.
Results:
After initiation of BBTV and the addition of Epic AIMS, compliance with obtaining three metrics on documentation of patient identification (two electronic signatures, start and stop times of transfusion, and blood volume transfused) was improved during a one-year period to > 96%. Pre-Epic audits had shown a mean compliance of only 86%, mainly reflecting a lack of paper blood component requisitions.
Conclusion:
By implementing BBTV and using a novel intraoperative documentation process within the Epic AIMS, a safer process of blood transfusion in the ORs was initiated and documentation improved.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Random Error