Related Experiment Video
Updated: Feb 3, 2026

Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
First dorsal compartment musculotendinous avulsion accompanied by close radial styloid fracture: Case report
Emre Anıl Özbek1, Mehmet Armangil2, Sırrı Sinan Bilgin2
1Yozgat City Hospital, Orthopedics and Traumatology Department, Yozgat City Hospital, 66100 Viyana Avenue, Yozgat, Turkey.
Introduction:
Radial styloid fracture and concomitant first dorsal compartment proximal musculotendinous avulsion is extremely rare injury. This togetherness is difficult to diagnose fully on routine physical examination.
Presentation Of Case:
In this study, we present a thirty nine year old male patient who suffered musculotendinous avulsion injury of the extensor pollicis brevis (EPB) tendon and abduc- tor pollicis longus (APL) tendon that is rarely accompanied by a closed, non-displaced radial styloid fracture developed following an in-car traffic accident. Diagnosis of avulsion was made with preop- erative magnetic resonance imaging (MRI) and the fracture was fixed with open reduction. The measurements of isometric APL and EPL muscle strength for two thumb were performed using a digital hand dynamometer, no statistically significant difference was found between the muscle strengths of the affected and non-affected thumbs at the postoperative second year follow- up (p > 0.05).
Discussion:
The literature does not hold enough cases to establish the grounds for hypotheses related to the injury mechanism in the 1 st extensor tendon musculotendinous injuries ac- companying radial styloid fractures. Although the diagnosis of the injury in our case was inadver- tently made with preoperative MRI, the routine application of MRI does not seem to be cost-effec- tive.
Conclusion:
We suggest that checking and assuring the intactness of the 1 st extensor compartment with a gentle traction during surgery should be a routine step in the treatment of radial styloid fractures treated with open reduction.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Compartment Models: Two-Compartment Model
Compartment Models: Single-Compartment Model
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Three-Compartment Open Model
Data Reporting and Recording

