Background:
Ruptured tiny intracranial aneurysms (TIAs) have been challenging both for endovascular and neurosurgical interventions. Thus, we aimed to evaluate the safety and efficacy of low-profile visualized intraluminal support (LVIS) device in the treatment of ruptured TIAs (rTIAs).
Material And Methods:
Among 761 intracranial aneurysms which were treated either surgically or endovascularly, 32 rTIAs underwent stent-assisted coiling with LVIS device between 2014 and 2017. Patient data were reviewed retrospectively. Clinical and radiological outcomes were recorded at discharge and mid-term follow-up.
Results:
Mean patient ages were 53 ± 14.5 years. Mean aneurysm size was 2.28 ± .53 mm (range, 1-2.9 mm) with a mean dome:neck ratio of 1.08 (range, .75-2.14). The LVIS stents were successfully implanted in all patients. Mean follow-up period was 9.3 ± 1.9 months (range, 6-15 months). Immediate angiographic evaluation demonstrated complete occlusion in 13 (40.6%) patients, while neck remnant and residual sac were observed in 12 (37.5%) and 7 (21.9%), respectively. All patients had moderate disability (mRS 2-3) at discharge. Number of aneurysms with complete occlusion significantly increased and 82.1% of the patients (23 of 28) demonstrated complete occlusion at follow-up (P = .0015). Among these, 27 had good outcome (mRS 0-1; 96.9%) with significant improvement compared to discharge (P = .0001). There was no recurrence or enlargement of the residual aneurysms. Additionally, there were no procedure-related complications except the one (3.6%) showing asymptomatic stenosis of the posterior cerebral artery in follow-up imagings.
Conclusions:
Stent-assisted coiling of rTIAs with LVIS device provides high rates of technical success and complete occlusion at mid-term follow-up with an excellent safety profile.
More Related Videos
Related Concept Videos
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Aneurysm I: Introduction
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Aneurysm IV: Nursing Management
Aneurysm III: Interprofessional Care