Related Experiment Video
Updated: Feb 3, 2026

Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Repeatability of dynamic contrast enhanced vp parameter in healthy subjects and patients with brain tumors
Moran Artzi1,2, Gilad Liberman1, Deborah T Blumenthal2,3
1Sagol Brain Institute, Tel Aviv Sourasky Medical Center, Tel-Aviv, Israel.
Purpose:
To study the repeatability of plasma volume (vp) extracted from dynamic-contrast-enhanced (DCE) MRI in order to define threshold values for significant longitudinal changes, and to assess changes in patients with high-grade-glioma (HGG).
Methods:
Twenty eight healthy subjects, of which eleven scanned twice, were used to assess the repeatability of vp within the normal-appearing brain tissue and to define threshold values for significant changes based on least-detected-differences (LDD) of mean vp values and histogram comparisons using earth-mover's-distance (EMD). Sixteen patients with HGG were scanned longitudinally with eight patients scanned before and following bevacizumab therapy. Longitudinal changes were assessed based on defined threshold values in comparison to RANO criteria.
Results:
The threshold values for significant changes were: LDD = 0.0024 (ml/100 ml, 21%) for mean vp and EMD = 4.14. In patients, in 20/24 comparisons, no significant longitudinal changes were detected for vp within the normal-appearing brain tissue. Concurring results were obtained between changes in lesion volume (RANO criteria) and LDD or EMD values in cases diagnosed with progressive-disease, yet in about 50% of cases diagnosed with partial-response preliminary results demonstrated significant increase in vp despite significant reductions in lesion volume. In two patients, these changes preceded progression detected at follow-up scans. In general, a good concordance was obtained between LDD and EMD.
Conclusion:
This study shows high repeatability of vp and provides threshold values for significant changes in longitudinal assessment of patients with brain tumors. Preliminary results suggest the use of vp-DCE parameter to improve assessment of therapy response in patients with high-grade-glioma.
More Related Videos
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Self-Evaluation: Self-Enhancement and Self-Verification
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Wave Parameters
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Dynamic Equilibrium