Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
Right Ventricular Septal Pacing Using a Thin Lumenless Pacing Lead and Delivery System with a Deflectable Catheter
Takeya Suzuki1, Tadashi Fujino1, Masaya Shinohara1
1Department of Cardiovascular Medicine, Toho University Faculty of Medicine.
Abstract:
The SelectSecure™ lead system (SSLS), which is composed of a thin lumenless, active-fixation lead and a deflectable catheter, is approved for use in Japan. This study aimed to evaluate the long-term clinical outcomes of right ventricular (RV) septal pacing with the SSLS along with the system's safety and electrical performance. A total of 129 patients were divided into the following 3 groups: the RV septal pacing with the SSLS group (SSP, n = 21); the RV septal pacing with the conventional lead group (Septal, n = 77); and the RV apical pacing with the conventional lead group (Apical, n = 31). All lead-related complications and pacing parameters during follow-up were compared among the groups. The clinical outcome was heart failure-associated hospitalization. The SSP and Septal groups showed significantly shorter paced QRS duration than the Apical group. During the follow-up for a mean of 49.5 ± 13.1 months, no lead-related complications occurred in any of the groups. A case of pericardial effusion occurred in the SSP group, but cardiac tamponade did not occur, and it spontaneously resolved. The ventricular pacing threshold after the follow-up period was higher in the SSP group than in the other 2 groups. There was no difference in the primary heart failure hospitalization among the 3 groups. The SSLS could be effective in producing a narrow QRS width with RV septal pacing, but its pacing threshold was higher than conventional leads in the chronic phase.
Related Concept Videos
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Methods Of Healthcare Delivery System
Managed Care System:
The managed care system is designed to control the cost while maintaining the quality of care. The patient's care from admission to discharge is planned by the primary care provider or the case manager, also known as the gatekeeper. In a managed care system, the number of care providers is...