Severe aortic regurgitation due to a Lunderquist Extra-Stiff Wire Guide during transcatheter aortic valve
Daisuke Hachinohe1, Marco B Ancona, Antonio Colombo
1San Raffaele Scientific Institute, Via Olgettina 60, 20132 Milan, Italy; EMO-GVM Centro Cuore Columbus, Via Michelangelo Buonarroti, 48, 20145 Milan, Italy; Sapporo Heart Center, Sapporo Cardio Vascular Clinic, 8-1, Kita-49 Higashi-16, Higashiku, 0070849 Sapporo, Japan. heartbond.8@gmail.com.
No abstract available in PubMed .
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Regurgitation I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...