Aim:
The aim of this study was to analyze the clinical outcomes after using an innovative implant system characterized by a modern platform-switched Morse taper connection and an osteo growth induction titanium surface (a particular type of SLA surface). Peri-implant bone loss (PBL) and implant success rate were examined after a 1- to 3-year follow-up.
Methods:
The study was conducted as a cross-sectional analysis on all patients treated from January 2011 to December 2014 using CLC CONIC implants. Implants were divided into 3 main groups, based on the duration of the follow-up (1 year, 2 years, and 3 years), then subgrouped by diameter, length, and type of prosthetic rehabilitation to compare differences in PBL. X-rays were taken at the time of surgery, at prosthetic loading, at 1 year, and then annually thereafter. Previously-established success criteria were used to assess the implants. Frequency analyses and comparisons between the means (with 95% CI) were conducted for the statistical analysis of the data collected.
Results:
One hundred twenty patients met inclusion and exclusion criteria, and completed the follow-up, and were thus eligible for the study, with a total of 261 CLC CONIC implants. The mean follow-up was 22.45 months. No implants failed, giving an overall success rate of 100%. The average PBL at 1-year follow-up was 0.047 mm, at 2 years it was 0.128 mm, and at 3 years it was 0.236 mm.
Conclusions:
The CLC CONIC implant system had a high success rate after 1 to 3 years of follow-up, in line with previous reports in the scientific literature. Combining platform switching with the Morse taper connection enabled stable bone levels to be achieved in the short to medium term.
Related Concept Videos
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Dietary Connections
Induction
A...
Introduction to Connective Tissues
Classification of Connective Tissues
Connective Tissue Proper
Connective tissue proper is the most abundant class of connective tissues. As its name implies, it predominantly connects different tissues in the body. Depending on the cell types, ground substance, viscosity, and fiber types in the ECM, connective tissue proper is further categorized into loose and dense....
Embryonic Connective Tissues
The mesenchyme is the first connective tissue that emerges in the developing embryo. It consists of loosely arranged multipotent mesenchymal cells and reticular fibers in the extracellular matrix. This loose arrangement allows easy migration of cells, which is essential for germ layer positioning, patterning, and organ morphogenesis during embryonic development.