Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Kei Asayama1,2, Takeshi Fujiwara3, Satoshi Hoshide3,4
1Department of Hygiene and Public Health, Teikyo University School of Medicine, Tokyo.
Abstract:
: Studies using ambulatory blood pressure (BP) monitoring have shown that BP during night-time sleep is a stronger predictor of cardiovascular outcomes than daytime ambulatory or conventional office BP. However, night-time ambulatory BP recordings may interfere with sleep quality because of the device cuff inflation and frequency of measurements. Hence, there is an unmet need for obtaining high quality BP values during sleep. In the last two decades, technological development of home BP devices enabled automated BP measurements during night-time. Preliminary data suggest that nocturnal home BP measurements yield similar BP values and show good agreement in detecting nondippers when compared with ambulatory BP monitoring. Thus, nocturnal home BP measurements might be a reliable and practical alternative to ambulatory BP monitoring to evaluate BP during sleep. As the use of home BP devices is widespread, well accepted by users and has relatively low cost, it may prove to be more feasible and widely available for routine clinical assessment of nocturnal BP. At present, however, data on the prognostic relevance of nocturnal BP measured by home devices, the optimal measurement schedule, and other methodological issues are lacking and await further investigation. This article offers a systematic review of the current evidence on nocturnal home BP, highlights the remaining research questions, and provides preliminary recommendations for application of this novel approach in BP management.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Changes in Skin Color: Clinical Perspectives
Albinism
Albinism is a genetic disorder that affects (completely or partially) the coloring of skin, hair, and eyes. The defect is primarily...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
The Evidence for Evolution
Blood Pressure