Related Experiment Video
Updated: Feb 3, 2026

Isolation of Small Noncoding RNAs from Human Serum
Published on: June 19, 2014
Development and validation of a sensitive LC-MS/MS method for the estimation of scopolamine in human serum
Suresh Kumar Swaminathan1, James Fisher2, Nicole K Brogden3
1University of Minnesota, Department of Pharmaceutics, College of Pharmacy, Minneapolis, MN United States.
Abstract:
Scopolamine is an anticholinergic alkaloid that is widely used in the form of a transdermal system to manage nausea associated with motion sickness. Currently available methods to quantify scopolamine require large sample volumes and involve cumbersome sample preparation. In this work, a simple method for the rapid separation and sensitive quantification of scopolamine in human serum was developed. Scopolamine was extracted from 0.5 mL of human serum using solid-phase extraction. The extracted samples were injected onto Zorbax XDB-C18 column (4.6 × 50 mm, 1.8 μm, and 600 bar) on an Agilent 1200 series HPLC. The chromatographic separation involved gradient elution with water and acetonitrile containing 0.1% v/v formic acid as a mobile phase. The samples were quantified in positive ion mode using a TSQ Quantum triple quadrupole mass spectrometer. The assay was validated and found to be linear over a concentration range of 5-5000 pg/mL. The total assay precision and accuracy was 6.3% and 96%, respectively. The lower limit of quantification (LLOQ) of the assay was 5 pg/mL. The assay was used in a human pharmacokinetic study to measure the concentration of scopolamine in serum after an administering scopolamine as transdermal delivery system or as an intravenous bolus dose.
More Related Videos
08:26Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018
09:57Development and Validation of a Quantitative PCR Method for Equid Herpesvirus-2 Diagnostics in Respiratory Fluids
Published on: March 17, 2016
Related Concept Videos
Reliability and Validity
In Vitro Drug Release Testing: Overview, Development and Validation
Development of Analytical Methods
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Data Validation
Key parameters for method validation include: