Comparison of breast cancer detection and depiction between planar and rotating synthetic mammography generated from breast tomosynthesis
Related Experiment Video For Artificial intelligence
Updated: Feb 3, 2026

Orthotopic Transplantation of Breast Tumors as Preclinical Models for Breast Cancer
Published on: May 18, 2020
Alejandro Rodriguez-Ruiz1, Susanne Lardenoije1, Alex J T Wanders2
1Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, the Netherlands.
Purpose:
To compare breast cancer detection and depiction between planar synthetic mammography (SM) and rotating synthetic mammography (RM) generated from digital breast tomosynthesis (DBT).
Materials And Methods:
In a fully-crossed multi-reader multi-case (MRMC) study, three radiologists retrospectively reviewed 190 cases (27 malignant, 31 benign, 132 normal), once with SM alone and once with RM alone, the DBT stack of slices was not reviewed. Lesions were scored using BI-RADS® and level of suspiciousness (1-10). Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were computed using MRMC Analysis of Variance using the open-access software iMRMC. Additionally, readers were asked to make a visual grading analysis (VGA) on visibility of calcifications and soft tissue lesions (1-5 scale with 5 = Excellent visualization). The VGA scores were analyzed using the visual grading characteristics (VGC) method.
Results:
On average, the AUC was similar between SM and RM (0.66 versus 0.67, P = 0.818). The sensitivity was equivalent (0.62 versus 0.60, P = 0.794), while specificity was significantly lower in SM than in RM (0.66 versus 0.72, P = 0.028). Radiologists significantly (P < 0.05) preferred the display of all types of lesions in RM over SM. The average reading time per case was higher for RM than for SM (30 s versus 23 s, P < 0.05).
Conclusion:
Radiologists achieve similar cancer detection with RM as with SM. They prefer the 3D-like rotating representation of soft tissue lesions and calcifications in comparison to the 2D visualization, which might improve their specificity, but at the expense of longer reading time.
Related Concept Videos
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Synthetic Biology
Golden rice
Golden rice is a genetically modified...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Gauss's Law: Planar Symmetry
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...