Dynamic contrast-enhanced MRI perfusion of normal muscle in adult hips: Variation of permeability and
Mazen El Rafei1, Pedro Teixeira2, Laurène Norberciak3
1Lille Regional University Hospital, Musculoskeletal Imaging Department, University of Lille Nord de France, Lille, France.
Abstract:
The purpose of this prospective study was to ascertain the degree of variation of semi-quantitative and permeability parameters on DCE-MRI of normally appearing striated muscles. Dynamic contrast-enhanced MRI of the right hip was performed in 20 women and 24 men. Mean age was 39.1 ± 12.4 years. Two regions of interest (ROI) were drawn in twelve muscles of anterior, medial and gluteal compartments: a free-form ROI covering the largest muscle section and a smaller elliptical ROI. Semi-quantitative and permeability parameters were calculated using the extended Tofts model. Statistical analysis was performed with a linear mixed model to assess perfusion parameters variation. Intra- and inter-observer agreements were assessed. The intra-observer agreement was considered to be good for free-form ROI (minimum Intra-Class Coefficient (ICC) = 0.72) and moderate for elliptical ROI (minimum ICC = 0.51), while the inter-observer agreement was considered to be bad in both cases (minimum ICC = 0.11). There was a high inter-individual variation in most of the perfusion parameters evaluated. The average coefficients of variation were: Time To Peak = 9%, Area Under the Curve = 44%, Ve = 61%, Kep = 90%, Initial Slope = 99%, and Ktrans = 128%. A considerable variation in resting muscle perfusion parameters was seen. This could lead to errors in the analysis of muscle DCE-MRI studies or oncologic/non oncologic studies using muscle as a referential. Further studies targeted on acquisition protocols and post-processing software are necessary to improve the performance of muscle MR perfusion.
Related Concept Videos
Variation: Normal Distribution, Range, and Standard Deviation
Bioavailability Enhancement: Drug Permeability Enhancement
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...


