The Feasibility of Using Volumetric Phase-Contrast MR Imaging (4D Flow) to Assess for Transjugular Intrahepatic
Joseph W Owen1, Nael E Saad2, Glenn Foster3
1Department of Radiology, University of Kentucky College of Medicine, 800 Rose Street, HX315A, Lexington, KY 40536-0293.
Four-dimensional (4D) flow MRI shows promise for detecting transjugular intrahepatic portosystemic shunt (TIPS) patency and stenosis. Further research is needed to confirm its utility in assessing TIPS dysfunction.
Area of Science:
- Medical Imaging
- Radiology
- Cardiovascular Imaging
Background:
- Transjugular intrahepatic portosystemic shunt (TIPS) creation is a common procedure for managing portal hypertension.
- Monitoring TIPS patency and detecting complications like stenosis or occlusion is crucial for patient outcomes.
- Current monitoring methods may have limitations, necessitating advanced imaging techniques.
Purpose of the Study:
- To evaluate the feasibility of using four-dimensional (4D) flow MR imaging for assessing the patency, stenosis, or occlusion of TIPS.
- To compare the diagnostic accuracy of 4D flow MRI with Doppler ultrasound and venography.
Main Methods:
- A volumetric phase-contrast sequence was employed for 4D flow MRI of TIPS in adult patients.
- Particle tracing and quantitative velocity measurements were used for qualitative and quantitative assessments.
- Technical success was defined by successful segmentation and flow measurement.
- Doppler US, venography, and clinical follow-up served as reference standards.
Main Results:
- 4D flow MRI was technically successful in 69.6% of patient encounters (16/23).
- The technique correctly identified stenosis in 3 cases (true positives) based on focal turbulence and abnormal velocities.
- It accurately identified patent TIPS in 7 cases (true negatives) with normal flow patterns.
- Six cases showed discordant results, with no evidence of dysfunction during follow-up.
Conclusions:
- 4D flow MR imaging is a feasible technique for detecting TIPS patency and stenosis.
- Additional research is necessary to establish its role in assessing TIPS dysfunction.
- The study highlights the potential of 4D flow MRI as a non-invasive tool for TIPS monitoring.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Phase Transitions
Phase Diagrams
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...