Related Experiment Video
Updated: Feb 3, 2026

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Resonance-Frequency Modulation for Rapid, Point-of-Care Ebola-Glycoprotein Diagnosis with a Graphene-Based
Arnab Maity1, Xiaoyu Sui1, Bing Jin1
1Department of Mechanical Engineering , University of Wisconsin-Milwaukee , 3200 North Cramer Street , Milwaukee , Wisconsin 53211 , United States.
Abstract:
Recent outbreaks of Ebola-virus infections in several countries demand a rapid point-of-care (POC)-detection strategy. This paper reports on an innovative pathway founded on electronic-resonance-frequency modulation to detect Ebola glycoprotein (GP), on the basis of a carrier-injection-trapping-release-transfer mechanism and the standard antibody-antigen-interaction principle within a dielectric-gated reduced graphene oxide (rGO) field-effect transistor (GFET). The sensitivity of Ebola detection can be significantly enhanced by monitoring the device's electronic-resonance frequency, such as its inflection frequency ( fi), where the phase angle reaches a maximum (θmax). In addition to excellent selectivity, a sensitivity of ∼36-160% and ∼17-40% for 0.001-3.401 mg/L Ebola GP can be achieved at high and low inflection-resonance frequencies, respectively, which are several orders of magnitude higher than the sensitivity from other electronic parameters (e.g., resistance-based sensitivity). Using equivalent circuit modeling for contributions from channel and contact, analytical equations for resonance shifts have been generalized. When matching with the incoming ac-measurement signal, electronic resonance from the phase-angle spectrum evolves from various relaxation processes (e.g., trap and release of injected charges at surface-trap sites of the channel-gate oxide and channel-source or drain interfaces) that are associated with a characteristic emission frequency. Using charge-relaxation dynamics, a high-performance bio-FET sensing platform for healthcare and bioelectronic applications is realized through resonance shifting.
Related Concept Videos
Resonance
Matrix Proteoglycans and Glycoproteins
Frequency-dependent Selection
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Interdisciplinary Care: The Health Care Team-I
Physicians
The physician's primary responsibility is to diagnose illness and direct the medical or surgical treatment of the condition. The authority to admit patients to a healthcare agency or institution and practice care within that setting is granted to physicians by the healthcare agency or institution...
Interdisciplinary Care: The Health Care Team-II
Physical Therapist
A physical therapist (PT) aims to restore function or prevent additional impairment in a patient following an injury or disease. Massage, heat, cold, water, sonar waves, exercises, and electrical stimulation are some treatments used by PTs to treat...

