Telemonitoring system for patients with chronic kidney disease undergoing peritoneal dialysis: Usability assessment
Marcos Antonio Martínez García1, Martha Socorrro Fernández Rosales1, Eduardo López Domínguez2
1General Hospital of Zone No. 11,Instituto Méxicano del Seguro Social, Xalapa, Veracruz, Mexico.
Abstract:
There are two million people with chronic kidney disease (CKD) worldwide. In Mexico, it is estimated that by 2025, there will be 212 thousand CKD cases. Among the renal replacement treatments, peritoneal dialysis (PD) exists either in the continuous ambulatory (CAPD) or automated (APD) mode, which requires continuous monitoring and strict control. Thus, several software systems have been proposed to perform reliable remote monitoring of patients using PD but also to achieve the goal with effectiveness, efficiency and satisfaction; i.e., in software engineering, this is called usability. However, few studies have addressed usability issues using case studies with patients and medical staff in real domains. In this paper, we present a usability assessment of a telemonitoring system for patients with CKD on peritoneal dialysis treatment through a case study with patients and medical staff of the Mexican Institute of Social Security (IMSS). The usability evaluation was carried out through the application of two satisfaction instruments. These instruments evaluated multiple usability criteria, such as navigability, interactivity, motivation, satisfaction, and applicability. The results obtained from the usability evaluation show that, on average, the services offered by the system have 91.3% acceptance by users (patient-doctors), with the APD and CAPD exchange data registration services having the highest acceptance for patients, with a positive perception of 94.5% and 92.3%, respectively. Meanwhile, for the doctors and nurses, the alarm reception for patients in a risk situation was highest with 95% acceptance. Based on the obtained results, the evaluated telemonitoring system holds wide acceptance, satisfaction, and applicability from patients' and doctors' perspectives. It is also noted that the evaluated system considers and satisfies the requirements and suitable parameters that should be monitored in PD treatment according to studies presented in the literature.
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Chronic Kidney Disease I: Introduction
Peritoneal Dialysis I: Introduction and Procedure
Chronic Kidney Disease II: Clinical Manifestations
Chronic Kidney Disease III: Interprofessional Care
Chronic Kidney Disease IV: Nursing Management