Related Experiment Video
Updated: Feb 3, 2026

Measurement of Carotenoids in Perifovea using the Macular Pigment Reflectometer
Published on: January 29, 2020
A free-standing wire scattering technique to monitor calibration variations of the DIII-D density profile
L Zeng1, G Wang1, T L Rhodes1
1Physics and Astronomy Department, University of California, Los Angeles, California 90095, USA.
Abstract:
Real-time phase calibration of the ITER profile reflectometer is essential due to the long plasma duration and expected waveguide path length changes during a discharge. Progress has been recently made in addressing this issue by employing a phase calibration technique on DIII-D that monitors calibration variations that occur during each plasma discharge. By installing a thin free-standing metallic wire (1 mm diameter) near the end of the overmoded waveguide transmission system (oriented perpendicular to the waveguide axis), the round-trip phase shift from the wire is detected simultaneously with the plasma phase shifts. Variations in the reflectometer round trip path length (∼26 m) are then calculated after each DIII-D plasma discharge, allowing the calibration phase to be accurately monitored and updated. The round-trip reflectometer path length is observed to vary by ∼3 mm (root mean square value) during a typical DIII-D discharge. Using the variations in calibration phase, the density profile measurement accuracy can be improved. Since the wire retro-reflected power is ∼0.01 of the plasma signal, minimal effect is observed on the reflected signal from the plasma. Importantly, through a suitable choice in wire diameter, the calibration signal can be made approximately independent of the V-band reflectometer launch polarization. This is particularly important on DIII-D since orthogonal X- and O-mode polarized beams are coupled into the same transmission waveguide and launch antenna.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
08:31The Calibration and Use of Capacitance Sensors to Monitor Stem Water Content in Trees
Published on: December 27, 2017
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Standing Waves
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Modes of Standing Waves - I