Related Experiment Video
Updated: Feb 3, 2026

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Published on: November 7, 2017
Application of a Hall sensor for pulsed magnetic field measurement in the FAT-CM FRC experiments
A Hosozawa1, J Sekiguchi1, T Asai1
1College of Science and Technology, Nihon University, Chiyoda-ku, Tokyo 101-8308, Japan.
Abstract:
Collisional merging experiments of a field-reversed configuration (FRC) plasma at the super-Alfvénic velocity have been conducted in the FAT (FRC Amplification via Translation)-CM (Collisional Merging) device. In the experiments, two FRCs are collided and merged in a confinement section with a quasi-static confinement magnetic field. Therefore, it is necessary to measure the high-frequency pulsed magnetic field superposed on a quasi-stationary signal. The magnetic field is generally measured by a magnetic coil probe in the pulse discharge experiments; however, in such measurements, errors arise in the low-frequency band in the conducted FRC experiments. Therefore, a Hall sensor has been applied for low-frequency magnetic field measurements in the FAT-CM experiments. Calibration of the Hall sensor involves confirming that the sensor has a sufficient response speed and linear characteristics for the magnetic field with a rising time of approximately 240 µs and that its output voltage does not saturate up to a magnetic field of 0.7 T. Combination of the Hall sensor and the magnetic coil probe ensures a comprehensive measurement of the magnetic field in the range of FAT-CM experiments. In this study, accurate magnetic measurements were performed in a collisional merging experiment in the FAT-CM device by using a combined magnetic diagnostic system.
More Related Videos
04:46Changing the Direction and Orientation of Electric Field During Electric Pulses Application Improves Plasmid Gene Transfer in vitro
Published on: September 12, 2011
06:17Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Related Concept Videos
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
The Hall Effect
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...
Special considerations while measuring pulse