Characterization of the Mercury pulsed power x-ray source spectrum using multichannel density aerogel Cherenkov
K D Meaney1, Y Kim1, H W Herrmann1
1Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
Abstract:
The Aerogel Cherenkov Detector for Cygnus (ACD/C) is a time-dependent, x-ray spectral detector that uses SiO2 aerogels spanning an index of refraction (n = 1.02-1.07) corresponding to a 1.1-2.3 MeV x-ray energy threshold. The ACD/C was developed for pulsed power x-ray sources like Cygnus located at the Nevada National Site and Mercury located at the Naval Research Laboratory (NRL). Aerogels sit between the measurement capabilities of gas (>2 MeV) and solids such as fused silica (>0.3 MeV). The detector uses an aluminum converter to Compton scatter incoming x-rays and create relativistic electrons, which produce Cherenkov light in an aerogel or a fused silica medium. The ACD/C was fielded at the NRL when Mercury was tuned to produce up to 4.8 MeV endpoint bremsstrahlung. Despite a high radiation and electromagnetic interference background, the ACD/C was able to achieve high signal over noise across five aerogel densities and fused silica, including a signal to noise for a 1.1 MeV aerogel threshold. Previous experiments at Cygnus observed a signal that was comparable to the noise (1×) at the same threshold. The ACD/C observed time-resolved rise and fall times for different energy thresholds of the photon spectrum. Monte Carlo simulations of the ACD/C's aerogel response curves were folded with a simulation of Mercury's photon energy spectrum and agree within the error to the observed result.
Related Concept Videos
The Electromagnetic Spectrum
The Electromagnetic Spectrum
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...