Conceptual design for resistive bolometer system with multiple apertures for measurement of total radiated power in

Ryuichi Sano1, Masakatsu Fukumoto1, Tomohide Nakano1

  • 1Naka Fusion Institute, National Institutes for Quantum and Radiological Science and Technology, Naka 311-0193, Japan.

Related Concept Videos

Design Example: Resistive Touchscreen01:14

Design Example: Resistive Touchscreen

A device engineer plays a crucial role in designing user interfaces for mobile devices. One such interface is the resistive touchscreen, which fundamentally consists of two metallic layers: a flexible upper layer and a rigid lower layer, separated by a narrow gap. The high resistance between these two layers is a key characteristic of this design.
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
736
Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
17.9K
Bioavailability Study Design: Single Versus Multiple Dose Studies01:11

Bioavailability Study Design: Single Versus Multiple Dose Studies

Bioavailability studies are essential for understanding how a drug is absorbed, distributed, metabolized, and excreted in the body. These studies assess the extent and rate at which the active pharmaceutical agent becomes available at the site of action. The design of bioavailability studies can involve single-dose or multiple-dose regimens, each with distinct advantages and limitations.Single-dose studies are the preferred approach due to their simplicity and reduced drug exposure for...
243
Design Example: Measuring Distance Between Two Points with Obstructions01:10

Design Example: Measuring Distance Between Two Points with Obstructions

When measuring distances in areas with physical obstructions, such as a lake in a field, surveyors must employ techniques to calculate accurate lengths without direct line measurements. One effective method is the offset technique, which allows for precise distance estimation over inaccessible stretches.In this scenario, a surveyor must measure a side of an area that crosses a lake. Since the measuring tape cannot span the lake, the surveyor begins by establishing a baseline that aligns with...
401
Nuclear Power02:36

Nuclear Power

Controlled nuclear fission reactions are used to generate electricity. Any nuclear reactor that produces power via the fission of uranium or plutonium by bombardment with neutrons has six components: nuclear fuel consisting of fissionable material, a nuclear moderator, a neutron source, control rods, reactor coolant, and a shield and containment system.
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
9.5K
Group Design02:01

Group Design

The most basic experimental design involves two groups: the experimental group and the control group. The two groups are designed to be the same except for one difference— experimental manipulation. The experimental group gets the experimental manipulation—that is, the treatment or variable being tested—and the control group does not. Since experimental manipulation is the only difference between the experimental and control groups, we can be sure that any differences between...
10.5K