Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Using a 3D-Printed Holder for Simultaneous Multiple Electroacupuncture Operation
Published on: September 1, 2023
Protective Effect of Electroacupuncture at Zusanli on Myocardial Injury in Septic Rats
Lijian Zhang1, Zhenjun Huang1, Xian Shi2
1Department of Rehabilitation of the 309 Hospital of People's Liberation Army, Beijing 100091, China.
Abstract:
The protective effect of electroacupuncture (EA) at Zusanli points (ST36) on myocardial injury in a model of sepsis was observed. Forty-eight male Sprague-Daley rats were subjected to sepsis by cecal ligation and puncture (CLP) and randomly divided into 4 groups (n=12; A: sepsis + EA; B: sepsis + sham acupuncture; C: sepsis + vagotomy; D: sepsis + vagotomy + EA). Bilateral points were stimulated (2mA, 2-100 Hz) for 1 hour. Abdominal vagotomy was performed in groups C and D. At 6h after CLP, the plasma activity of creatine kinase-MB (CK-MB) was determined. A part of cardiac muscle was harvested for evaluating levels of tumor necrosis factor (TNF-α), nitric oxide (NO), myeloperoxidase (MPO), and the rate of water content. The activities of CK-MB, TNF-α, NO, and MPO and the rate of water content in group A were significantly lower than those of the other groups 6h after CLP. EA after vagotomy showed less anti-inflammatory and protective effects. The results indicated that EA obviously reduced the increased levels of the proinflammatory factors at 6h after CLP, and vagotomy could weaken or eliminate the effects of EA. Cholinergic anti-inflammatory pathway is one of the main mechanisms of cardioprotective effect of EA.
More Related Videos
05:58Mouse Electroacupuncture Fixation Device Fabrication for Electroacupuncture Pretreatment in Diabetic Cardiomyopathy Mouse Model
Published on: April 18, 2025
04:33Effects of Different Connection Modes of Electroacupuncture on Electrocardiogram and Nerve Discharge in Rats
Published on: January 3, 2025
Related Concept Videos
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Protecting Self-Esteem
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Personal Protective Equipment