Office blood pressure measurement types: Different methodology-Different clinical conclusions
George S Stergiou1, Konstantinos G Kyriakoulis1, Anastasios Kollias1
1Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Abstract:
The measurement of blood pressure in the office (OBP) remains the basis for hypertension diagnosis and management for more than half a century. Despite the increasing use of out-of-office blood pressure measurement using home and less so ambulatory monitoring and their endorsement by hypertension societies, at present and for some time to come it is likely that in many people the diagnosis and management of hypertension will be based on OBP measurement alone. OBP measurement is a very variable method affected by multiple factors, which have major impact on the OBP level, reproducibility and prognostic ability. Thus, there are several types of OBP measurement, depending on the device type, conditions, observer's presence and the number of readings. The 4 main OBP types are: Type I: Auscultatory OBP in clinical practice; Type II: Automated attended OBP in clinical practice; Type III: Research setting OBP; Type IV: Unattended automated OBP. These OBP types have different standardization level, different reproducibility, different clinical relevance and different thresholds for hypertension diagnosis. Unless the methodological details of OBP measurement are reported, any conclusions based on such measurements in clinical research and in practice are questionable.
More Related Videos
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...