Related Experiment Video
Updated: Feb 2, 2026

Using SecM Arrest Sequence as a Tool to Isolate Ribosome Bound Polypeptides
Published on: June 19, 2012
Sudden cardiac arrest in patients without overt heart disease: a limited value of next generation sequencing
Abstract:
INTRODUCTION Unexplained sudden cardiac arrest (SCA), occurs in up to 10% of patients and is often attributed to an inherited arrhythmia syndrome. Family screening and genetic testing may help clarify the cause of unexplained SCA. OBJECTIVES We aimed to assess the usefulness of clinical evaluation and genetic testing in patients after unexplained SCA and in their families. PATIENTS AND METHODS In the years 2014-2017, we studied 44 unrelated patients after unexplained SCA and 96 of their relatives. All patients and relatives underwent comprehensive cardiac evaluation. In 31 patients with SCA, next generation sequencing (NGS) was performed. The Kaplan-Meier survival curve was constructed to compare the event-free survival depending on clinical diagnosis or genotype. An adverse event was defined as an adequate implantable cardioverter-defibrillator discharge. RESULTS Based on the clinical evaluation, diagnosis was established in 39% of probands (long QT syndrome 21%; short QT syndrome 7%; Brugada syndrome 7%; catecholaminergic polymorphic ventricular tachycardia, 2%; and early repolarization syndrome, 2%). Ventricular arrhythmia was identified in the relatives of 19% of probands. In 18 of the 31 probands (54.8%), 23 rare gene variants were identified, of which only 2 were classified as pathogenic. The event-free survival over a median of 4.5 years was similar in patients with or without clinical diagnosis and in carriers and noncarriers of a rare genetic variant. CONCLUSIONS This study shows the significance of an extensive clinical assessment in unexplained SCA victims and their relatives. Routine genetic testing by NGS has low diagnostic and prognostic value.
More Related Videos
Related Concept Videos
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features....
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Catheterization II: Right Heart Catheterization
Rheumatic Heart Disease I: Introduction
Ischemic Heart Disease: Overview
Atherosclerosis, the primary malefactor, orchestrates this dangerous condition. It manifests as the accumulation of fatty deposits, akin to insidious plaques, within arterial walls. As time elapses, these plaques metamorphose, hardening and...

