In vitro comparison of linear vs triangular screw configuration to stabilize complete uniarticular parasagittal
Raphael Labens1, Nurul H Khairuddin2, Mark Murray1
1School of Animal and Veterinary Sciences, Faculty of Science, Charles Sturt University, Wagga Wagga, New South Wales, Australia.
Objective:
To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.
Study Design:
Experimental.
Sample Population:
Fourteen equine cadaver limbs/horses.
Methods:
Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.
Results:
Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded = .003; Ploaded < .001). The type of repair was not correlated with fracture gap grades at unloaded mid and loaded dorsal P1 sites.
Conclusion:
Repair of uniarticular complete parasagittal fractures with a triangular screw configuration improved in vitro fracture gap reduction and stability.
Clinical Significance:
Triangular lag screw repair likely improves biomechanical conditions during postoperative weight bearing.
Related Concept Videos
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Stability of Equilibrium Configuration: Problem Solving
Problem-solving in the context of the stability of equilibrium configuration...
Sternberg's Triangular Theory of Love
Electron Configuration of Multielectron Atoms
Rectangular and Triangular Pulse Function
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...