Related Experiment Video
Updated: Feb 2, 2026

Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
Published on: March 4, 2015
High-Order Hadamard-Encoded Transmission for Tissue Background Suppression in Ultrasound Contrast Imaging: Memory
Abstract:
Hadamard-encoded multipulses (HEM) transmit has recently been utilized for tissue background suppression in ultrasound contrast imaging to enhance the contrast-to-tissue ratio (CTR). Nonetheless, the second-harmonic component in HEM transmit results in residual tissue background after decoding and, thus, compromises the detection of contrast microbubbles. Theoretically, high-order HEM transmit can produce harmonic-free background but the memory effect, which considers the nonlinear contribution of previous bit waveform into the next one in the progress of harmonic generation, may limit the achievable tissue suppression. In this paper, three possible harmonic-free pairs using time-shifted subtraction (SH1, SH2, and SH3) in the fourth-order Hadamard decoding are analyzed and experimentally compared using hydrophone measurement and B-mode imaging. Moreover, the orthogonal decoding (OD) of HEM transmit is also proposed with pulse-inversion harmonic suppression (PIHS) to remedy memory effect on the tissue background. Results show that SH3, which utilizes the third and fourth rows for decoding, provides the lowest magnitude of tissue background among all possible decoding pairs and performs comparably to the reference PI and amplitude-modulation sequence in terms of CTR. For PIHS-OD, the pulse subtraction effectively removes the harmonic interferences from memory effect and, thus, further improves the CTR by 5.4 dB compared to SH3. For high-order HEM transmit, PIHS-OD can help to eliminate the residual tissue background due to memory effect and is comparable to Hadamard decoding in temporal resolution and possible motion artifacts.
Related Concept Videos
The Z-Scheme of Electron Transport in Photosynthesis
Encoding
Automatic processing involves the encoding of details like time, space, frequency, and the meaning of words, usually done without conscious...
Background and Environment Affect Phenotype
An example of how genetic background affects phenotype can be seen in horses. The Extension gene in horses is responsible for their coat color. A wild-type gene (EE) produces black pigment in the coat, while a mutant gene (ee) produces red pigment. A...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
System of Memory

