Optofluidic Fabry-Pérot Micro-Cavities Comprising Curved Surfaces for Homogeneous Liquid Refractometry-Design,

Noha Gaber1,2, Yasser M Sabry3, Frédéric Marty4

  • 1Laboratoire Electronique, Systèmes de Communication et Microsystèmes, Université Paris-Est, ESIEE Paris, ESYCOM EA 2552, 93162 Noisy-le-Grand, France. ngaber@zewailcity.edu.eg.

Micromachines
|November 9, 2018
PubMed

Related Concept Videos

Design Example: Setting a Curve Using Design Data01:09

Design Example: Setting a Curve Using Design Data

Designing and plotting a curve using field data requires precise calculations and execution. A horizontal curve with a radius of 200 meters and an intersection angle of 20 degrees is established using the method of perpendicular offsets from the long chord. The long chord, which spans between the curve's endpoints, is calculated to be 69.46 meters in length. To maintain accuracy in plotting, intervals of 3 meters are selected along the chord.The engineer determines the offset distances for each...
236
Experimental Designs01:16

Experimental Designs

An experimental design is a systematic process that allows researchers to evaluate the relationship between dependent and independent variables. There are three widely used types of experimental design - pre-experimental design, true experimental design, and quasi-experimental design. In pre-experimental design, the researcher compares the data before and after some interventions or treatments. The true-experimental design has more than one purposefully created group, a commonly measured...
17.4K
Bending of Curved Members - Neutral Surface01:16

Bending of Curved Members - Neutral Surface

In curved beams, unlike straight beams, the stress distribution across the cross-section is not uniform due to the beam's curvature. This non-uniformity arises because the neutral axis, where stress is zero, does not align with the centroid of the section. In a curved beam, the strain varies along the section as a function of the distance from the neutral axis.
Consider the curved member described in the previous lesson. According to Hooke's law, which relates stress to strain within the...
528
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
3.5K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
3.0K
Hydrostatic Pressure Force on a Curved Surface01:04

Hydrostatic Pressure Force on a Curved Surface

Hydrostatic pressure on curved surfaces is a fundamental concept in fluid mechanics with broad applications in the civil engineering field. When fluid is in contact with a curved surface, as in a reservoir, dam, or storage tank, it exerts pressure that varies in magnitude and direction along the curved surface. To assess the total hydrostatic force exerted by the fluid on a curved structure, engineers typically isolate the fluid volume adjacent to the surface and analyze the forces acting on...
2.5K