Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Low contrast material dose coronary computed tomographic angiography using a dual-layer spectral detector system in
Seitaro Oda1, Hiroko Takaoka2, Kazuhiro Katahira2
11 Department of Diagnostic Radiology, Kumamoto University , Kumamoto , Japan.
Objective::
To evaluate the effects of virtual monochromatic imaging (VMI) using dual-layer spectral detector CT on the image quality of coronary CT angiography (CCTA) acquired by using a low contrast material (CM) dose.
Methods::
We used a VMI 50keV protocol with a 50% CM dose (140 mgI kg-1) to scan 30 patients with renal insufficiency and a 120 kVp with the standard CM dose (280 mgI kg-1) to scan 30 controls without renal insufficiency. Quantitative parameters, including CT attenuation, image noise, and contrast-to-noise ratio (CNR), were measured. The visual image quality factors of contrast enhancement, image noise, beam-hardening artefact, vessel sharpness, and overall image quality were scored on a 4-point scale.
Results::
The mean CT attenuation of the ascending aorta was significantly higher for 50 keV VMI than for 120 kVp. Image noise was significantly lower under the 50 keV VMI. CNR and the mean visual score for contrast enhancement were significantly higher for 50 keV VMI. There were no significant differences in the other visual image quality parameters between the two protocols.
Conclusion::
Dual-layer spectral detector CT using 50 keV VMI enabled reducing the CM dose by 50 % without CCAT image quality degradation in patients with renal insufficiency.
Advances In Knowledge::
The VMI 50 keV protocol using dual-layer spectral detector CT and a CM dose reduced by 50 % (140 mgI kg-1) can improve the diagnostic image quality of CCTA.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Relative Risk
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...