Optimal Pulmonary Valve Annulus Diameter for Annulus Preservation in Tetralogy of Fallot May Be Far Smaller Than
Dong-Hee Kim1, Ji Hye Lee1, Eun Seok Choi1
1Division of Pediatric Cardiac Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Abstract:
We hypothesized that optimal pulmonary valve annulus (PVA) diameter upon annulus preservation (AP) in tetralogy of Fallot (ToF) may be far smaller than the normal diameter. Retrospective review of the 61 consecutive patients who underwent ToF repair between January 2016 and September 2017 was performed. Median age, body weight, and median PVA (Z) at repair were 166 days (interquartile range, IQR, 141-182 days), 7.4 kg (IQR, 6.6-8.0 kg), and -1.83 (IQR, -2.56 to -0.90), respectively. Upon AP, subvalvar and supravalvar obstructions were completely eliminated, leaving a pressure gradient only at the valve level. AP was achieved in 58 patients (95.1%). Pulmonary valve intervention comprised commissurotomy in 35 patients, commissurotomy with bougination in 8 patients, and transannular patching in 3 patients. For 15 patients, the pulmonary valve was left intact. Median PVA diameter measured by Hegar dilator after PV intervention was 8 mm (IQR, 7-9 mm), which was 3.9 mm (IQR, 2.3-4.3 mm) smaller than normal dimension and translated to a PVA (Z) of -1.85 (IQR, -2.40 to -0.78). Postrepair right and left ventricular pressure ratio was 0.47 ± 0.12. During the median follow-up duration of 353 days (IQR, 191-482 days), 4 patients (including 3 who underwent transannular patching) developed significant pulmonary regurgitation. Freedom from reintervention for PS, significant PS, and PR at 1 year was 92.4%, 83.2%, and 90.6%, respectively. Optimal PVA for AP may be far smaller than the normal diameter. Minimizing PV intervention upon AP can prevent superfluous postoperative PR.
Related Concept Videos
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Normal Distribution
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Optimal Foraging
Applications of Normal Distribution
The heights of 15 to 18-year-old males from Chile from 1984 to 1985 followed a normal distribution. The mean height is 172.36...