Related Experiment Video
Updated: Feb 2, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Double factor single shot to diminish complications in cryoballoon ablation procedures for atrial fibrillation
Ermengol Vallès1,2, Begoña Benito3,4, Jesús Jiménez3
1Electrophysiology Unit, Department of Cardiology, Hospital del Mar, Universitat Autònoma de Barcelona, 25-29 Passeig Marítim, 08003, Barcelona, Spain. ermengolvalles@mac.com.
Purpose:
Cryoballoon ablation (CBA) has become a standard treatment for recurrent atrial fibrillation (AF). There is need for improved CBA protocols. We aimed to demonstrate that a new protocol including minimum temperature (minT) reached could reduce procedure times and complications.
Methods:
A new double factor protocol (DFP), based on the performance of one single shot per vein with variable duration, and conditional bonus shot, determined by time-to-effect (TTE) and minT, was compared with the conventional protocol (CP), with at least two shots per vein. Procedure parameters, complications, and efficacy were compared.
Results:
We prospectively included 88 consecutive patients treated with the DFP. These were compared to the previous consecutive 69 patients treated with CP. All procedures were performed with 28-mm second-generation balloon. Acute pulmonary vein (PV) isolation was similar (98.6% vs. 98.9% in CP vs. DFP, p = 0.687). Procedure and ablation times favored DFP over CP (120 vs. 134 min, p = 0.003; and 1051 vs. 1475 s, p < 0.001; respectively). A composite of major and minor complications was significantly reduced in the DFP compared to the CP (18.8% vs. 6.8%, p = 0.02; respectively). Within a follow-up of 18 months, freedom from AF was 79.7% in CP and 78.4% in DFP (Log-rank 0.501). Paroxysmal AF and absence of PV potentials predicted better arrhythmia outcomes (HR 2.14 for paroxysmal vs. persistent, p = 0.031; and HR 1.61 for absence vs. presence of PV potentials, p = 0.01).
Conclusions:
The novel DFP results in reduced complication rates and procedure times, with similar success rates compared with a conventional strategy.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Related Concept Videos
Hemodialysis II: Procedure and Complications
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Fixing Double-strand Breaks
Pneumonia III: Complications and Assessment