Related Experiment Video
Updated: Feb 2, 2026

Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025
Design and use of a novel substrate for simple, rapid, and specific early detection of anthrax infection
1Research and Development, List Biological Laboratories, Inc., Campbell, California, United States of America.
Abstract:
Bacillus anthracis is a major biological warfare threat. The inhalation form of infection can kill quickly. While antibiotic treatment is effective, if diagnosis is delayed, the rapidly produced toxin may already be present in lethal amounts. This report describes a fast, sensitive, specific and accurate method for detection of active infection by Bacillus anthracis in plasma. One of the virulence factors, anthrax lethal factor, is an endopeptidase present in blood early in the infection. However, the use of peptidic substrates to detect endopetidases is problematic in plasma due to the presence of other proteases and the likelihood of nonspecific cleavage of the substrate. The fluorescently labeled peptide substrate MAPKKide Plus designed in this study is not cleaved by plasma proteases and thus is specific for lethal factor. Three detection strategies are described. Two include enrichment by capture from plasma using lethal factor antibody-coated microtiter plates or similarly coated immuno-tubes. The captured lethal factor is exposed to the MAPKKide Plus, and the amount of cleavage is determined either by HPLC or microplate reader. Concentration of lethal factor using the antibody-coated plates aplnd HPLC allows for detection of less than 5 pg lethal factor/ml of neat plasma after 2 hours of incubation. Using antibody-coated immuno-tubes, 20 pg lethal factor/ml plasma can be detected in 5 hours by a simple end point read of fluorescence in a microplate reader. For a third strategy, the substrate is added directly to diluted plasma, and cleavage is monitored by the increase in fluorescence as a function of time. The limit of detection by this simple method is 25 ng lethal factor/ml of plasma in 15 minutes, 5 ng/ml after 45 minutes, and <1 ng lethal factor/ml of plasma after 5 hours.
More Related Videos
09:10Combination of Adhesive-tape-based Sampling and Fluorescence in situ Hybridization for Rapid Detection of Salmonella on Fresh Produce
Published on: October 18, 2010
07:47Reverse Transcription Loop-Mediated Isothermal Amplification RT-LAMP Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020
Related Concept Videos
Group Design
Factorial Design
Design Example: Designing a Residential Plumbing System
Design Example: Designing Water Slide
Bernoulli's principle determines the water's velocity along the slide....
Design Example: Design of an Irrigation Channel
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...