Leadless Cardiac Pacemaker (LCP) without Diagnostic Relevant Artifacts in DualSource and DualEnergy-CT Examinations
Sebastian D Reinartz1, Robin F Gohmann1, Felix Hardt1
1Department of Diagnostic and Interventional Radiology, University Hospital, RWTH Aachen University, Pauwelsstr. 30, 52074 Aachen, Germany.
Rationale And Objectives:
To identify the influence and artifact burden in cardiac CT imaging of a leadless cardiac pacemaker (LCP) performed with all three generations of DualSource CT (DSCT) Scanners.
Materials And Methods:
The LCP was examined in DSCT scanners of the first to third generation using DualEnergy (DECT) and DSCT as well as alterations of the current-time product. For DECT examinations, virtual monoenergetic images were computed manually on a dedicated workstation. Virtual voltage was manually selected by subjective assessment of the lowest artifact burden. Systematic variations of the pacemaker angle to the gantry were assessed, too. The angle was successively increased by 10°, ranging from 0° to 90°. Artifact burden was quantified on a five-point Likert scale (1- no artifacts, 2- few artifacts, 3- moderate artifacts, 4- many artifacts, and 5- massive artifacts). Likert values of 1-3 were considered diagnostic and assessed by two board-certified radiologists in consensus.
Results:
In total, 200 examinations were analyzed, a mean Likert value of 1.93 ± 0.61 was found overall. None of the images were assessed Likert value >3. The positioning evaluation showed a clear and significant reduction of artifact burden toward lower angles, (0°: 1.4 ± 0.5 vs. 90° 2.55 ± 0.51). At scanner level, second-generation DSCT performed significantly better (1.68 ± 0.47) than both other scanners. Comparison of technique (DECT vs. DSCT) revealed a significantly improved image quality in DSCT examinations.
Conclusion:
LCP can be safely examined in DSCT scanner of the first to third generation with the evaluated protocols and techniques, which are currently in use. Artifact burden can be significantly reduced by aligning or approaching the LCP's longitudinal axis toward the scanner's z-axis.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...