Related Experiment Video
Updated: Feb 2, 2026

Probe-based Confocal Laser Endomicroscopy of the Urinary Tract: The Technique
Published on: January 10, 2013
Findings for Differentiated Thyroid Carcinoma by γ-Camera-Based and Uptake-Probe-Based Methods in Comparison with
Biju Menon1,2, Atanu Bhattacharjee2,3, Sandip Basu4,2
1Radiation Medicine Centre (BARC), Tata Memorial Hospital Annexe, Mumbai, India.
Abstract:
The objective of the study was to calculate neck uptake by γ-camera-based and uptake-probe-based methods and compare it with uptake by diagnostic whole-body and neck radioiodine scanning in thyroid carcinoma patients. Methods: Of the 46 patients, 14 were male (average age, 47.5 y) and 32 female (average age, 38 y). All had already undergone thyroidectomy followed by 131I treatment at least once and came to the institute after 6 mo for follow-up. As per the institutional protocol, they underwent scanning 72 h after administration of a low-dose capsule (111-148 MBq) of 131I, and the uptake was calculated by both probe- and camera-based methods using medium-energy parallel-hole collimators. Results: The neck was negative for uptake in 24 patients by both the probe-based method (with 0.1% as the cutoff) and the camera-based method, as well as by the scan. The neck was positive for uptake in 10 patients by both methods and by the scan. In 10 patients, the neck was positive for uptake by the probe-based method but negative by the camera-based method and the scan; in most of these cases, nontarget counts contributed to high scatter radiation. In 2 patients, the neck was negative for uptake by the probe-based method but positive by the camera-based method and the scan. Thus, the two methods were concordant in 34 of the 46 patients (74%) but discordant in 12 (26%). On the basis of these results, we propose that 0.03% be the cutoff for positivity for the camera-based method. In 85.7% of patients with negative scan results and systemic metastases near the neck (n = 7), an uptake cutoff of 0.1% resulted in positive results. All patients had true-negative results with a camera-based cutoff of 0.03%. In view of this discordance between the probe-based method and the scan, we further propose that 0.2%, rather than 0.1%, be the cutoff for positivity for the probe-based method in order to reduce false positivity. Conclusion: In thyroid carcinoma patients undergoing 131I low-dose scans, camera-based uptake is as reliable as, and can substitute for, probe-based uptake in evaluating functioning metastases near the neck or nonspecific high physiologic accumulation.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Base Excision Repair
The first step of...
Weak Base Solutions
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
DNA Base Pairing

