Related Experiment Video
Updated: Feb 2, 2026

Transcutaneous Assessment of Renal Function in Conscious Rodents
Published on: March 26, 2016
Assessment of renal function before contrast media injection: right decisions based on inaccurate estimates
Václav Ptáčník1, David Zogala1, Daniela Skibová1,2
1Institute of Nuclear Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Salmovská 3, 120 00, Praha 2, Czech Republic.
Objectives:
Information on renal function required before specified radiological examinations with contrast agents is usually obtained through prediction equations using serum creatinine and anthropometric data. The aim of our study was to demonstrate discrepancy between poor prediction and good diagnostic accuracy of glomerular filtration rate (GFR) estimated by prediction equations.
Methods:
In 50 patients, reference GFR was measured as plasma clearance of 51-chromium labeled ethylene-diamine-tetraacetic-acid (51Cr-EDTA) and compared with GFR assayed by creatinine clearance (CC) and estimated by Cockcroft-Gault prediction equation (CG). For comparisons, CC and CG were considered as continuous, categorical, and binary variables. Accuracy of the reference GFR prediction was expressed in terms of prediction errors and diagnostic accuracy indices.
Results:
As continuous variable, CG estimated individual values of GFR with large prediction error exceeding that of CC. As categorical variable, it classified the patient stage of chronic kidney disease (CKD) with medium diagnostic accuracy of 74% (CKD 3) and 62% (CKD 4). As binary variable, CG classified individual patient's GFR below 30 and 60 ml/min/1.73 m2 with good diagnostic accuracy of 80 and 94%, respectively. Performance of other prediction equations did not significantly differ from CG.
Conclusions:
Despite large variance and poor prediction accuracy of individual GFR estimates, most of them correctly classified individual patient's GFR below specified level. Results of prediction equations thus should be used and reported exclusively as binary variables, while numerical values of GFR, if required, should be measured by more accurate radionuclide or laboratory methods.
Key Points:
• Radiological guidelines on contrast media require estimation of glomerular filtration rate to assess kidney function before specified contrast examinations. • Estimated glomerular filtration rate is obtained through prediction equations using serum creatinine and anthropometric data as predictors. • While numerical estimates of glomerular filtration rate are inaccurate (their prediction accuracy is poor), diagnostic accuracy of binary estimates (ability to classify patient's glomerular filtration rate below or above a specified level) is very good.
More Related Videos
07:31A Computerized Functional Skills Assessment and Training Program Targeting Technology Based Everyday Functional Skills
Published on: February 13, 2020
15:43Assessment of Mitochondrial Functions and Cell Viability in Renal Cells Overexpressing Protein Kinase C Isozymes
Published on: January 7, 2013
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Serum Studies: Renal Function Tests
Renal Regulation of Acid-Base Balance
In the kidneys, cells within the proximal convoluted tubules (PCT) and the collecting ducts secrete hydrogen ions (H+) into the tubular fluid. Specifically, in the PCT, Na+/H+ antiporters secrete H+ while reabsorbing Na+.
However, the intercalated cells in...
Decision Making
Automatic decision-making is fast, intuitive, and relies on gut feelings...
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...