Related Experiment Video
Updated: Feb 2, 2026

Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
Efficacy of a paclitaxel-eluting biliary metal stent with sodium caprate in malignant biliary obstruction: a
Sung Ill Jang1, Kyu Taek Lee2, Jung Sik Choi3
1Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea.
Backgrounds:
The placement of a self-expandable metal stent (SEMS) is widely used in patients with unresectable malignant biliary obstructions, but SEMSs are susceptible to occlusion by tumor ingrowth or overgrowth. The efficacy and safety of a novel paclitaxel-eluting biliary metal stent incorporating sodium caprate (MSCPM-III) were compared prospectively with those of a covered metal stent (CMS) in patients with malignant biliary obstructions.
Methods:
Patients with unresectable distal malignant biliary obstructions (n = 106) were prospectively enrolled in this study at multiple treatment centers. Stents were placed endoscopically: MSCPM-III in 54 patients and CMS in 51 patients. The patients received systemic chemotherapy regimens according to their disease characteristics.
Results:
The two groups did not differ significantly in basic characteristics or mean follow-up period. Stent occlusion occurred in 14 patients who received MSCPM-III and in 11 patients who received CMS. Time to recurrent biliary obstruction (RBO) and survival time did not differ significantly between the two groups (P = 0.84 and P = 0.29, respectively). However, tumor size at 2 months after stent insertion was significantly decreased in patients in the MSCPM-III group with bile duct cancers or those who experienced stent migration compared with the CMS group. Complications, including cholangitis and pancreatitis, were found to be acceptable in both groups.
Conclusions:
Although compared with a CMS the MSCPM-III did not significantly influence time to RBO or survival duration in patients with malignant biliary obstructions, MSCPM-III reduced tumor volume and was used safely in humans.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Alkali Metals
Table 1: Properties of the alkali metals
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Self-Efficacy
High-Performance Liquid Chromatography: Elution Process