Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Innovative Methodology for Implanting and Securing Neural Probes in the Rodent Spinal Cord
Published on: July 12, 2024
Comprehensive strategy to reduce the incidence of lead dislodgement for cardiac implantable electronic devices
Muhammad R Afzal1, Sarah Horner1, Nancy B Matre1
1Division of Cardiovascular Medicine, Department of Internal Medicine, Electrophysiology Section, Ross Heart Hospital, The Wexner Medical Center at the Ohio State University Medical Center, Columbus, OH, USA.
Background:
Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD.
Methods:
The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted.
Results:
There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD.
Conclusion:
Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.
Related Concept Videos
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Electron Affinity
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Electron Transport Chains
The ETC is comprised of...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...

