Arthroscopic Treatment of Ankle Instability - Allograft/Autograft Reconstruction

João Teixeira1, Stephane Guillo2

  • 1Departament of Orthopaedics and Traumatology, Centro Hospitalar de Entre o Douro e Vouga, rua Dr. Cândido de Pinho, Santa Maria da Feira 4520-211, Portugal.

Foot and Ankle Clinics
|November 12, 2018
PubMed

Related Concept Videos

Ankle Joint01:10

Ankle Joint

The ankle is formed by the talocrural joint (crural = leg). It consists of the articulations between the talus bone of the foot and the distal ends of the tibia and fibula of the leg. The superior aspect of the talus bone is square-shaped and has three areas of articulation. The top of the talus articulates with the inferior tibia. This is the portion of the ankle joint that carries the body weight between the leg and foot. The sides of the talus are firmly held in position by the articulations...
3.0K
Microtubule Instability02:17

Microtubule Instability

Microtubules are hollow cylindrical filaments having a diameter of approximately 25 nm and a length that varies from 200 nm to 25 μm. GTP-bound tubulin subunits form αβ-heterodimers for microtubule assembly. These core building blocks interact longitudinally, polymerizing into protofilaments. The protofilaments then interact with one another through lateral bonding forces to form stable cylindrical microtubules. These cylindrical filaments are dynamic as they undergo repeated...
6.2K
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
729
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.9K
Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
997
Treatment Resistant Cancers02:56

Treatment Resistant Cancers

Cancer is the second leading cause of death in the United States. A cancer cell is genetically unstable and hence can mutate faster. They can also modify their microenvironment and escape immune surveillance. The difficulties in treating cancer are further compounded by the emergence of rapid resistance to anticancer drugs. The most common ways to attain resistance in cancer cells include alteration in drug transport and metabolism, modification of drug target, elevated DNA damage response, or...
3.8K