Related Experiment Video
Updated: Feb 2, 2026

High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes
Published on: July 25, 2015
Is SBRT Boost Feasible for PET Positive Lymph Nodes for Cervical Cancer? Evaluation using Tumor Control Probability
Jeffrey E Snyder1, Addison B Willett1, Wenqing Sun1
1Department of Radiation Oncology, The University of Iowa, Iowa City, Iowa.
Purpose:
This study aimed to examine the feasibility of stereotactic body radiation therapy (SBRT) as an external beam radiation therapy boost to positron emission tomography (PET) positive lymph nodes (LN) in patients with cervical cancer and to evaluate overall tumor control probability (TCP) increase.
Methods And Materials:
Ten patients with cervical cancer and PET positive LN metastasis who received external beam radiation therapy (45 Gy), followed by a 3-dimensional conformal radiation therapy boost (5.4-9 Gy) and tandem-and-ovoid high-dose-rate brachytherapy (16-30 Gy) were retrospectively enrolled in this study. SBRT plans were generated using 21 Gy, 24 Gy, or 30 Gy as a replacement for 3-dimensional conformal radiation therapy boost. The 2 Gy-per-fraction equivalent dose maps were made using an α/β value of 10 for PET positive LNs and 3 for organs at risk (OARs). TCP values were calculated using a logistic TCP model, where 2 input parameters (D50 and Gamma50 = 2) were modeled by 2 clinical outcomes: our institution and the literature. OAR sparing was evaluated using Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) dose limits.
Results:
Thirty percent of 10 patients receiving conventional boost experienced recurrence. The TCP of the SBRT schemes was 88% ± 7% (97% ± 2%; 21 Gy), 96% ± 1% (99% ± 0%; 24 Gy), and 99% ± 1% (100% ± 0%; 30 Gy), and the conventional LN-boost TCP value was 25% ± 11% (58% ± 15%) when TCP input parameters were based on published clinical outcome data for LN SBRT treatments (institutional outcome data). The tumor coverage doses (D90) of the SBRT boost plans were on average 32.34 Gyαβ=10 (21 Gy), 37.78 Gyαβ=10 (24 Gy), and 55.54Gyαβ=10 (30 Gy) higher than the conventional LN boost plan. The QUANTEC OAR dose constraints were met for the bladder, rectum, and bowel in all cases for the SBRT LN 21 Gy group, and in 90% and 70% of cases in the SBRT LN 24 Gy and SBRT LN 30 Gy groups, respectively.
Conclusions:
An SBRT boost dose of 30 Gy can be delivered without compromising QUANTEC OAR limits. The use of SBRT increases TCP values, regardless of the input parameters.
Related Concept Videos
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Probability Laws
Chromatin Position Affects Gene Expression
Topologically Associated Domains (TADs)
The 3-dimensional positioning of chromatin in the nucleus influences the...
Criteria for Causality: Bradford Hill Criteria - II
Criteria for Causality: Bradford Hill Criteria - I
Probability Distributions
A discrete probability distribution is a probability distribution of discrete random variables. It can be categorized into binomial probability distribution and Poisson...