Pulsed Doppler fetal atrioventricular interval measurement: Assessment of a new image scoring method
Adélie Michau1, Laurence Gitz2, Francine Proulx3
1Departement of Obstetrics and Gynaecology, Hôpital Bicêtre, AP-HP, University Paris Sud, Kremlin Bicêtre, France; Department of Obstetrics and Gynaecology, Hôpital Antoine Béclère, APHP, University Paris Sud, Clamart, France.
Objectives:
We propose an image scoring method to improve the quality and the reproducibility of measurement of the AV interval before establishing reference tables of the measurements and studies on the prevention and treatment of first-degree AV block especially if the first child has been diagnosed AV block.
Method:
Prospective study from May 2015 to June 2016. Sonographers were asked to measure AV interval with pulsed Doppler in a five-chamber view in standard second-trimester screening before and after having received our image scoring method. Images were scored by 2 blinded reviewers.
Results:
The intra-class correlation coefficient (ICC) between the two reviewers for the overall score was 0.91. On average, the measurement quality increased by 2.5 points/10 (95% CI 1.0-4.0). In the second set of images, after the scoring method was given, the score stared at 6.50 for the first image, with a significant improvement of 0.18 (p = 0.016) per subsequent image comparing to a non significant improvement for the first set of image. There was a significant improvement in intra-observer reliability, ICC: 0.680 [95% CI 0.606-0.854] versus 0.458 [95% CI 0.140-0.651].
Conclusion:
The use of this scoring method is simple, reproducible and improves image quality and reproducibility of AV interval measurement in a five-chamber view.
Related Concept Videos
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Critical Numbers and the Closed Interval Method
Special considerations while measuring pulse