Intercondylar eminence fracture treated by resorbable magnesium screws osteosynthesis: A case series
A Gigante1, N Setaro1, M Rotini1
1Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Via Tronto, 10/A, 60126, Ancona, Italy.
Introduction:
Tibial spine avulsion fractures are mostly a paediatric injury which appropriate treatment is currently debated in literature. The choice between conservative and surgical treatment is based on the radiographic classification of Meyers-McKeever. The most diffused surgical techniques involve either internal fixation devices (screws) or bone tunnels fixation with resorbable sutures. Today, a third option is represented by resorbable magnesium screws which could combine the best features of the two classical systems. Objective of this study is to investigate the efficacy of these new devices in the surgical treatment of tibial spine avulsions.
Materials And Methods:
Since 2014 we have seen seven patients with tibial eminence fracture. Patients underwent clinical and radiological examination (MRI, CT scan) before surgery. Only 3 patients that presented with a grade III or IV lesion were treated surgically with internal fixation with magnesium resorbable screws. In post-operative follow-up, functional recovery was evaluated at 1, 2, 4, 6 and 12 months, clinically and by X-ray. Lysholm and IKDC scores were submitted at 1, 2, 6 and 12 months. MRI was repeated at 6 and 12 months.
Results:
All three surgical patients showed progressive clinical and functional improvement during the follow-up period. The first case showed a quicker overall recovery rate, which might be due to the lower grade of the lesion. Radiographs and MRI evaluation showed regular healing of the injury. The devices appeared completely resorbed at the 6 months follow-up and replaced by newly formed bone at the 12 months follow-up.
Conclusions:
The treatment of tibial spine avulsion fractures with arthroscopic reduction and internal fixation (ARIF) technique by magnesium resorbable screws seems to result in an excellent functional recovery without complications related to fixation devices, which were completely resorbed after 6 months and replaced by newly formed bone after 12 months. This new method could be considered as an alternative option to classic techniques by non resorbable fixation devices or bone tunnel fixation. Further studies are needed in order to evaluate the efficacy of these new devices in a wider group of patients.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Resistors In Series
In a series circuit, the...
Series Resonance
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
