Generating amorphous target margins in radiation therapy to promote maximal target coverage with minimal target size
1Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, TN 37232, USA.
Background And Significance:
This work provides proof-of-principle for two versions of a heuristic approach that automatically creates amorphous radiation therapy planning target volume (PTV) margins considering local effects of tumor shape and motion to ensure adequate voxel coverage with while striving to minimize PTV size. The resulting target thereby promotes disease control while minimizing the risk of normal tissue toxicity.
Methods:
This work describes the mixed-PDF algorithm and the independent-PDF algorithm which generate amorphous margins around a radiation therapy target by incorporating user-defined models of target motion. Both algorithms were applied to example targets - one circular and one "cashew-shaped." Target motion was modeled by four probability density functions applied to the target quadrants. The spatially variant motion model illustrates the application of the algorithms even with tissue deformation. Performance of the margins was evaluated in silico with respect to voxelized target coverage and PTV size, and was compared to conventional techniques: a threshold-based probabilistic technique and an (an)isotropic expansion technique. To demonstrate the algorithm's clinical utility, a lung cancer patient was analyzed retrospectively. For this case, 4D CT measurements were combined with setup uncertainty to compare the PTV from the mixed-PDF algorithm with a PTV equivalent to the one used clinically.
Results:
For both targets, the mixed-PDF algorithm performed best, followed by the independent-PDF algorithm, the threshold algorithm, and lastly, the (an)isotropic algorithm. Superior coverage was always achieved by the amorphous margin algorithms for a given PTV size. Alternatively, the margin required for a particular level of coverage was always smaller (8-15%) when created with the amorphous algorithms. For the lung cancer patient, the mixed-PDF algorithm resulted in a PTV that was 13% smaller than the clinical PTV while still achieving ≥99.9% coverage.
Conclusions:
The amorphous margin algorithms are better suited for the local effects of target shape and positional uncertainties than conventional margins. As a result, they provide superior target coverage with smaller PTVs, ensuring dose delivered to the target while decreasing the risk of normal tissue toxicity.
Related Concept Videos
Targeted Cancer Therapies
There are several types of targeted therapies against...
Targets for Drug Action: Overview
Receptors are either membrane-spanning or intracellular proteins, which upon binding a ligand, get activated and transmit the signal downstream to elicit a response. Drugs bind receptors, either mimicking the action of endogenous ligands or blocking the receptor activity to bring about a modified response. Nearly 35% of approved drugs target the G...
Target Cell Response to Hormones
Notably, the cellular response can be regulated by altering the number of receptors expressed in the cell. For example, prolonged exposure to elevated hormone levels results in a gradual decline or down-regulation in the number of receptors for that specific hormone on the cell surface. Conversely, in response to low hormone levels, cells may use up-regulation, producing an...
Generating Electromagnetic Radiations
Biological Effects of Radiation
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...