Related Experiment Video
Updated: Feb 2, 2026

Standard Test Method ASTM D 7998-19 for the Cohesive Strength Development of Wood Adhesives
Published on: May 17, 2020
EDTA Conditioning Increases the Long-term Microtensile Bond Strength to Sclerotic Dentin Mediated by Self-etch
Purpose:
To evaluate the immediate and 12-month microtensile bond strength (μTBS) of two self-etch adhesives on sclerotic dentin with or without previous EDTA conditioning. The conditioning pattern and the relative area of open dentinal tubules were also evaluated.
Materials And Methods:
Twenty-eight bovine incisors with naturally exposed sclerotic dentin were used. For μTBS testing, 20 teeth were divided into 4 groups (n = 5) according to the combination of the main factors: 1. adhesive (Clearfil SE Bond [CSE, Kuraray] and Adper SE Plus [ADSE, 3M Oral Care]); 2. surface treatment (previous conditioning with EDTA and previous conditioning with distilled water [DW]). The sclerotic surfaces were conditioned with either 17% EDTA or DW for 2 min prior to adhesive application. Composite buildups were constructed. Specimens were sectioned to obtain composite-dentin sticks (0.8 mm2) to be tested immediately or after 12 months (distilled water at 37°C) in tensile mode (0.5 mm/min). The conditioning pattern and the relative area of open dentinal tubules (OT) were evaluated in the remaining eight teeth. After adhesive application, the surfaces were rinsed off with acetone and ethanol. Then the surface was evaluated by SEM with image software. Data from μTBS and OT were submitted to three-way repeated measures ANOVA and data from OT were submitted to one-way repeated measures ANOVA. After, for both tests, Tukey's post-hoc test was applied (α = 0.05).
Results:
For both adhesives, EDTA resulted in the highest mean immediate μTBS (p = 0.002), which remained stable after 12 months of water storage (p < 0.38). CSE showed higher μTBS when compared to ADSE (p = 0.001). Degradation of the mean μTBS was observed for both adhesives only in the DW groups. Adhesive application plus with EDTA conditioning increased the OT area in comparison with only adhesive application (p < 0.001).
Conclusion:
EDTA conditioning increased the immediate microtensile bond strength in sclerotic dentin substrate and prevented degradation when associated with a self-etch adhesive.
More Related Videos
07:07Development of a Direct Pulp-capping Model for the Evaluation of Pulpal Wound Healing and Reparative Dentin Formation in Mice
Published on: January 12, 2017
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
Related Concept Videos
Bonding and Strength of Aggregate
EDTA: Conditional Formation Constant
For the equilibrium reaction of the metal with the...
Bond Energies and Bond Lengths
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Covalent Bonding and Lewis Structures
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...